Environment Lost in Enhanced Mode on Novell Network

ID: Q86175


The information in this article applies to:
  • Microsoft Windows versions 3.0, 3.0a, 3.1, 3.11
  • Microsoft Windows for Workgroups versions 3.1, 3.11


SYMPTOMS

When you run MS-DOS Prompt under Microsoft Windows or Windows for Workgroups in 386 enhanced mode on a Novell network, you may lose your environment parameters. You can view your MS-DOS environment settings by issuing the SET command at the MS-DOS command prompt before you start Windows, or at the MS-DOS Prompt under Windows.


WORKAROUND

If you are losing your MS-DOS environment variables, use the following troubleshooting steps to ensure a consistent MS-DOS environment:

  1. Make sure the correct Novell NetWare drivers are selected in Windows Setup. There are five NetWare selections under Windows 3.1 Setup:
    Novell NetWare (shell versions 3.21 and above)
    Novell NetWare (shell versions 3.26 and above)
    Novell NetWare (shell versions below 3.01)
    Novell NetWare (shell versions below 3.21)
    Novell NetWare 2.10 or above, or Novell NetWare 386
    To check which shell version you are currently using, issue the following command at the MS-DOS command prompt (you must be logged onto the network to issue this command):
    NETX I
    -or-
    NVER
    NOTE: If you are using NetWare version 3.32 (released for MS-DOS 6 support), use NETX.


  2. Verify that the VIPX.386 file is located in the Windows/SYSTEM directory.


  3. Ensure that the COMSPEC environmental variable is being set correctly in the CONFIG.SYS file. The following line should be present in the CONFIG.SYS file:
    
          SHELL=C:\DOS\COMMAND.COM C:\DOS\ /e:2048 /p 
    NOTE: The above line assumes that the COMMAND.COM file is located in the C:\DOS directory.


  4. Update the NETX and IPX to the most recent version. Windows version 3.1 supplies NETX.COM version 3.26 and an IPX.OBJ file that you can use to generate a Windows 3.1 compatible version of IPX.COM. Be sure to select
    Novell NetWare (shell versions 3.26 and above)
    in the Windows Setup.


  5. Update any supporting Novell files such as LOGIN.EXE to the most current version available.



MORE INFORMATION

The MS-DOS environment can also be lost or garbled if multiple protocols are installed on a single workstation. For example, a workstation might have drivers for the IBM DOS LAN Requester network and drivers for Novell NetWare installed. This allows the workstation to access both OS/2 LAN Servers and Novell NetWare servers. However, if the Windows Setup is configured for "IBM OS/2 Lan Server" instead of "Novell NetWare (shell version)", then the DOS environment will be lost or garbled when you run MS-DOS Prompt from Windows in 386 enhanced mode.

To correct this problem, make sure that the Novell NetWare drivers are loading, and that the LAN Server drivers are not. The Windows NetWare drivers need to be loaded for the Novell Network to run properly in 386 enhanced mode Windows.

The Novell products included here are manufactured by Novell, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words: 3.00 3.00a 3.10 3.11 3rdparty man VM net ware path

Keywords :
Version : WINDOWS:3.0,3.0a,3.1,3.11
Platform : WINDOWS
Issue type :


Last Reviewed: September 28, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.