Novell Server Disconnect Hangs Enhanced Mode Windows

ID: Q87984


The information in this article applies to:
  • Microsoft Windows versions 3.0, 3.0a, 3.1, 3.11


SYMPTOMS

If Microsoft Windows is running on a Novell workstation in 386 enhanced mode while connected to a Novell server, and the server stops functioning and/or disconnects the workstation, then the workstation may hang and display the error message:

System Error cannot read from device network.
This occurs even if Windows is installed in a standalone configuration. Novell is aware of the problem and is working to correct this.


WORKAROUND

To work around this problem run Windows in standard mode.

The NetWare product included here is manufactured by a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: 3.00 3.00a 3.10 stand alone stand-alone

Keywords :
Version : WINDOWS:3.0,3.0a,3.1,3.11
Platform : WINDOWS
Issue type :


Last Reviewed: October 13, 1999