Windows Err Msg: General Protection Fault in Module Calisto

ID: Q92632


The information in this article applies to:
  • Microsoft Windows versions 3.1, 3.11
  • Microsoft Windows Productivity Pack, version 3.1


SYMPTOMS

You may receive the following error message if you run Microsoft Productivity Pack for Windows version 3.1 with versions earlier than 2.05 of YourWay software:

General Protection Fault in Module Callisto


WORKAROUND

To correct this error with version 2.05 of YourWay, disable the YourWay software by removing C:\YOURWAY2\ywyqm.exe from the LOAD= line in the Windows WIN.INI file.


STATUS

Prisma Software has released version 3.0 of their YourWay product. This version does not install on the LOAD= line in the WIN.INI file, but generates the same error message if YourWay is running concurrently with Productivity Pack version 3.1.

Prisma is researching the problem.

YourWay software is manufactured by Prisma Software, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: 3.10 3.11 your way calisto 3rdparty

Keywords :
Version : WINDOWS:3.1,3.11; :3.1
Platform : WINDOWS
Issue type :


Last Reviewed: October 22, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.