Access Pack for Windows WIN.INI Settings
ID: Q99383
|
The information in this article applies to:
-
Microsoft Windows versions 3.0, 3.0a, 3.1, 3.11
SUMMARY
This article describes the WIN.INI file settings used by Access Pack
for Windows, version 3.0a. These entries are only added to your
WIN.INI file when you explicitly save setting changes using the Access
Utility provided with Access Pack.
WARNING: Be very careful when you modify WIN.INI file settings; refer
to the Access Pack WININI.WRI file for more information.
To change these settings, choose your settings using the Access
Utility, and then save them using the Save Parameter Changes to Disk
command from the File menu.
If you cannot run the Access Utility because of unsupported hardware,
you can add these entries to your WIN.INI file using a text editor,
such as Microsoft Windows Notepad. See the Access Pack WININI.WRI file
for more information about the structure of the WIN.INI file and
instructions on making changes.
MORE INFORMATION
The WIN.INI settings are describes below.
[FilterKeys] Section Settings
-----------------------------
On=<0 or 1>>
Default: 0
Purpose: Specifies if the Keyboard Response features (SlowKeys,
RepeatKeys and BounceKeys) are on or off when Windows is
started. If this setting is 0, these features are off until
activated using the keyboard or the Access Utility. If the
setting is 1, the features are on until deactivated.
OnOffFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should produce a rising or
falling audible tone to indicate when the Keyboard Response
features are turned on or off when using the keyboard. If this
setting is 0, no sound is emitted.
DelayBeforeAcceptance=<milliseconds>
Default: 1000
Purpose: Specifies how long a key must be held down before being
accepted.
AutoRepeatDelay=<milliseconds>
Default: 1000
Purpose: Specifies how long a key must be held down before it begins
automatically repeating.
AutoRepeatRate=<milliseconds>
Default: 500
Purpose: Specifies the amount of time between automatically repeated
keystrokes when a key is held down long enough to activate
the auto-repeat feature. Set this value to 32760 to turn off
auto-repeat altogether.
BounceTime=<milliseconds>
Default: 500
Purpose: Specifies amount of time a particular key should be ignored
after it is pressed and released once.
[StickeyKeys] Section Settings
-----------------------------
On=<0 or 1>
Default: 0
Purpose: Specifies if the StickyKeys feature is on or off when Windows
is started. If this setting is 0, these features are off
until activated using the keyboard or the Access Utility. If
the setting is 1, the feature is on until deactivated.
OnOffFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should produce a rising or
falling audible tone to indicate when the StickyKeys feature
is turned on or off with the keyboard. If this setting is 0,
no sound is emitted.
TriState=<0 or 1>
Default: 1
Purpose: Specifies whether pressing a modifier key by itself twice in
a row should cause the key to be locked down until it is
pressed a third time. If the setting is 1, the modifier keys
may be locked down using this procedure. If the setting is 0,
pressing a modifier key a second time releases the key.
TwoKeysOff=<0 or 1>
Default: 1
Purpose: Specifies whether pressing two modifier keys or a modifier and
a nonmodifier key simultaneously turns off the StickyKeys
feature. If this setting is 1, pressing two modifier keys or
one modifier key and a nonmodifier key at the same time
turns off the StickyKeys feature.
AudibleFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should indicate when a modifier
key is being latched, locked, or released by generating
audible tones. If this setting is 1, the system generates
these tones.
[MouseKeys] Section Settings
----------------------------
On=<0 or 1>
Default: 0
Purpose: Specifies if the MouseKeys feature is on or off when Windows
is started. If this setting is 0, this feature is off until
activated using the keyboard or the Access Utility. If the
setting is 1, the feature is on until deactivated.
OnOffFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should produce a rising or
falling audible tone to indicate when the MouseKeys feature
is turned on or off when using the keyboard. If this setting
is 0, no sound is emitted.
TimeToMaximumSpeed=<milliseconds>
Default: 3000
Purpose: Specifies the amount of time it takes the mouse cursor to
attain full speed when a mouse movement key is held down.
MaximumSpeed=<pixels-per-second>
Default: 40
Purpose: Specifies the maximum speed the mouse cursor can attain
when a mouse movement key is held down.
[ToggleKeys] Section Settings
-----------------------------
On=<0 or 1>
Default: 0
Purpose: Specifies if the ToggleKeys feature is on or off when Windows
is started. If this setting is 0, this feature is off until
activated using the keyboard or the Access Utility. If the
setting is 1, the feature is on until deactivated.
OnOffFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should produce a rising or
falling audible tone to indicate when the ToggleKeys feature
is turned on or off when using the keyboard. If this setting
is 0, no sound is emitted.
[TimeOut] Section Settings
--------------------------
On=<0 or 1>
Default: 0
Purpose: Specifies if the TimeOut feature is on or off when Windows is
started. If this setting is 0, this feature is off until
activated using the Access Utility. If the setting is 1 the
feature is on until deactivated.
OnOffFeedback=<0 or 1>
Default: 1
Purpose: Specifies whether the system should produce a falling tone to
indicate when the Access Pack features have been turned off
because of a time-out. If this setting is 0, no sound is
emitted.
TimeToWait=<minutes>
Default: 5
Purpose: Specifies the amount of time the system must be idle, with
no mouse or keyboard input, before all Access Pack features
is automatically turned off.
[GIDEI] Section Settings
------------------------
On=<0 or 1>
Default: 0
Purpose: Specifies if the SerialKeys feature is on or off when the
Access Utility is started. If this setting is 0, this feature
is off until activated using the Access Utility. If the
setting is 1, the feature is on until deactivated.
BaudRate=<baud-rate>
Default: 300
Purpose: Specifies the speed at which incoming SerialKeys data is
expected.
Port=<1, 2, 3, or 4>
Default: 1
Purpose: Specifies the serial port on which incoming SerialKeys data
is expected. If this setting is 1, the data is expected on
COM1; if the setting is 2, the data is expected on COM2,
and so on.
[ShowSounds] Section Settings
-----------------------------
Screen=<0 or 1>
Default: 0
Purpose: Specifies whether the screen should flash when Access Pack
detects that an application has generated a sound. This
setting is unavailable on some types of computer displays.
Caption=<0 or 1>
Default: 0
Purpose: Specifies whether the title bar of the foreground window
should flash when Access Pack detects that an application has
generated a sound.
KBCategory: kbref kbdisplay kbsound kbtool kbui kbhw
KBSubcategory: win30 win31
Additional query words:
video blink acces disabled handicap accessibility disabilities disability
Keywords : kbenable win31 win30 kbEnableSight kbEnableMove kbEnableHear kbEnableLearn
Version : WINDOWS:3.0,3.0a,3.1,3.11
Platform : WINDOWS
Issue type :