Programs Using Old Winsock.dll File May Not Work in Windows
ID: Q139384
|
The information in this article applies to:
-
Microsoft Windows 95
-
Microsoft Plus! for Windows 95
-
Microsoft Windows 98
SYMPTOMS
After you upgrade to a Windows version listed in the Applies To banner and
you install or try to use a Winsock program, the program may not run, or
you may receive the following error message when you try to run the
program:
The following system files have been replaced with older versions by a
program you recently ran. These files are currently in use and cannot
be automatically repaired. Windows may not run properly until you exit
and restart Windows so that these files can be automatically repaired.
C:\Windows\Winsock.dll
CAUSE
When you install Dial-Up Networking, TCP/IP, or the IPX/SPX-compatible
protocol in Windows, Setup renames the existing Winsock.dll file to
Winsock.old and installs a new suite of Windows Sockets 1.1 interface
files.
Current Winsock programs may not be compatible with the Windows
Winsock.dll file due to proprietary services in the program's version of
the file.
If the program you try to run is not compatible with the installed version
of the Winsock.dll file, you may receive an error message or the program
may not run.
RESOLUTION
To resolve this issue, use any one of the following methods:
- Connect to your Internet service provider using Dial-Up Networking.
Dial-Up Networking provides support for 16-bit and 32-bit Windows
Sockets programs.
For additional information about using Dial-Up Networking, view the
"Connecting to a network by using Dial-Up Networking" topic in Windows
95 Help or see the following article in the Microsoft Knowledge Base:
ARTICLE-ID: Q138789
TITLE : How to Connect to the Internet in Windows 95
- You may be able to use both your current Winsock program and the Windows
Winsock programs by following these steps:
- Copy the Winsock.old file from the Windows folder or the
Windows\System folder to the folder containing the program's
executable file.
- Rename the Winsock.old file in its new folder to Winsock.dll.
- Contact the manufacturer of the Winsock program to inquire about a
possible update.
MORE INFORMATION
The following Winsock programs may work if you place their version of the
Winsock.dll file in the program's folder:
- Chameleon
- CompuServe Internet Dialer or CompuServe Net Launcher
- FTP Software
- Internet In a Box
- Internet Office
- Mosaic In a Box
- NetCom Net Cruiser
- Pipeline
- Spry Air Series
- Trumpet
Additional query words:
98 rna ras
Keywords : kb3rdparty kberrmsg kbnetwork dun winplus win95 appscomp win98 kbAPI kbSDKPlatform kbWinsock kbGrpNet
Version : 95 98
Platform : WINDOWS
Issue type : kbprb