Pioneer DR-UA124X CD-ROM Drive Disables IDE Port

ID: Q188294


The information in this article applies to:
  • Microsoft Windows 98
  • Microsoft Windows 95


SYMPTOMS

You may see an exclamation point in a yellow circle next to an IDE port on the Device Manager tab in the System Properties dialog box. When this occurs, you cannot gain access to the CD-ROM drive connected to the IDE port.


CAUSE

This behavior can occur if you have a Pioneer DR-UA124X CD-ROM drive installed in your computer. The Pioneer DR-UA124X CD-ROM drive's firmware causes this behavior to occur.


RESOLUTION

Use any text editor (such as Notepad) to open the Autoexec.bat file in the root folder of drive C. Look for a line containing "Mscdex.exe," and then remove the "REM" statement at the beginning of the line. Save the changes, quit the text editor, and then restart your computer.

Keywords : kbenv kbhw win95 win98 cddrive
Version : WINDOWS:95
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: March 3, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.