Capture PrinterPort and Other Dialog Boxes Show Truncated Path

ID: Q205981


The information in this article applies to:
  • Microsoft Windows 98
  • Microsoft Windows 95


SYMPTOMS

When you view a captured printer port or a mapped network drive, the dialog boxes may display "\\..." instead of the correct Universal Naming Convention (UNC) path of \\servername\sharename. Also, when you attempt to use a program, the program may incorrectly interpret that the drive is not available and may create a new drive mapping.


CAUSE

This issue can occur if you have the Novell Client32 program installed. When the "\\" characters are missing, a program cannot correctly interpret the path because the drive does not match the normal UNC format.Because of this, the program incorrectly interprets that the UNC is not mapped and maps the next available drive (which also does not have "\\" in the UNC).


RESOLUTION

To resolve this issue, upgrade to the IntranetWare Client 2.2 or later. For information about how to do so, contact Novell.


MORE INFORMATION

The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words:

Keywords : kb3rdparty kbnetwork kbtool kbui
Version : WINDOWS:95
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: August 12, 1999