The information in this article applies to:
SYMPTOMS
When you use the Windows NT backup program, NTBACKUP.EXE, with a supported
tape unit connected to the same SCSI chain as the hard disk of a Quantum
ProDrive 1080s, the following error message may appear:
CAUSEThis problem occurs when the hardware termination on the hard disk of the Quantum ProDrive 1080s is not properly disabled. RESOLUTION
According to the Quantum hard disk documentation, the Quantum ProDrive
1080s has a TE jumper that needs to be removed in order to disable the
termination. However, in order to properly disable the termination, all
termination jumpers (not just the TE jumper) need to be removed.
Additional query words: prodnt 3.10
Keywords : |
Last Reviewed: February 4, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |