WINDOWS kb3rdparty kbbug3.50 The information in this article applies to:
SYMPTOMSIf you run the PowerSoft PowerBuilder Watcom database engine DB32W.EXE in a separate VDM, a General Protection Fault (GPF) occurs when another application tries to access the database through DB32W.EXE. In tests with Microsoft Query, the GPF occurred in <unknown> at 00C7:B40A. CAUSEWhen another application sets up ODBC, PowerBuilder's DB32W.EXE passes it a 16:16 pointer what is valid only in the VDM where DB32W.EXE is running. RESOLUTIONDB32W.EXE will run in a separate VDM if you check the Run In Separate Memory Space box in the Program Item Properties dialog box in Program Manager. It will also run in a separate VDM if you launch it with the START command. Run the querying application and DB32W.EXE in the same VDM. STATUSThis behavior is by design. Additional query words: prodnt memory violation
Keywords : |
Last Reviewed: February 5, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |