Setup Hangs with Buslogic BT-946C on Powerstation/Powerserver

ID: Q120473

3.10 3.50 3.51 4.0
WINDOWS
kbsetup kbhw kb3rdparty
The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.1, 3.5, 3.51, 4.0
  • Microsoft Windows NT Advanced Server version 3.1
  • Microsoft Windows NT Server versions 3.5, 3.51, 4.0


SUMMARY

If you have Micron Powerstation or Powerserver with Buslogic's BT-946C SCSI controller, Windows NT setup may hang without an error message while attempting to load Windows NT to complete the graphic portion of Setup.


MORE INFORMATION

According to Micron and Buslogic these steps usually solve the problem:

  1. Press CTRL-B to go to Buslogic Auto Configuration.


  2. Select Configure Device Menu.


  3. Select Disconnection Option.


  4. Set "Disconnection on all ID's except 0 and 1" to YES.


  5. If these were already set this way you may need to toggle them, because some hard drives do not support disconnection.


Buslogic Product Support does not recommend permanently changing the controller configuration as indicated above unless there is only one SCSI device attached to the controller. The procedure may disable the functionality of SCSI devices on the SCSI chain during certain I/O actions carried out by the OS.

If there are no scanning devices on this chain it is possible to Disable the SCAN MODE option, since this can cause problems with the installation of NT, according to Buslogic.

If this does not solve the problem, go to the Buslogic Auto Configuration and verify that the IRQ pin is set to pin A (the default) on the Powerstations and Powerservers. On P90 models this should be set to pin C (the default); the adapter is installed next to the power supply. Then verify that the IRQ being used is set to 15 and that in the "Advanced Options" the BIOS is set to use 4D8.

Additionally Buslogic BIOS should be flashed to the most recent version (1.40E as of 9/4/96) since this solves most setup or operational problems related to NT 3.51 and NT 4.0.

These steps solve most of the setup hang problems with Windows NT. You can get more assistance by contacting the vendors listed below:

  • Buslogic technical support: (408) 970-1414


  • Buslogic BBS: (408)492-1984


  • Micron Technologies technical support: (208)465-3434


The products discussed here are manufactured by Micron and Buslogic, vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding the products' performance or reliability.

Additional query words: prodnt hung stop vendor

Keywords :
Version : 3.10 3.50 3.51 4.0
Platform : WINDOWS
Issue type :


Last Reviewed: February 5, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.