Datarace RediModem Modem Error from RAS

ID: Q122901

3.50
WINDOWS
kbhw
The information in this article applies to:
  • Microsoft Windows NT Workstation version 3.5
  • Microsoft Windows NT Server version 3.5


SYMPTOMS

When using the internal version of the Texas Instruments Datarace RediModem to dial from Remote Access, the following error message appears:

Error 651: Your modem or other connecting device has reported an error.

The modem returns the following string:
<cr><lf> ERROR<cr><lf>

The initialization string included in the MODEM.INF that comes with Windows NT is incorrect for the internal version of this modem.


RESOLUTION

Texas Instruments has provided a corrected MODEM.INF section for this modem. Simply copy all the lines below into the MODEM.INF file which can be found in the %SYSTEMROOT%\SYSTEM32\RAS directory.


   [TI Internal - DataRace]
   ;Advanced features enabled, MAXCONNECT set to 38400
   DEVICETYPE=modem
   CALLBACKTIME=10
   DEFAULTOFF=compression
   MAXCARRIERBPS=14400
   MAXCONNECTBPS=38400

   <speaker_on>=M1
   <speaker_off>=M0
   <protocol_on>=\\N7
   <protocol_off>=\\N0
   <hwflowcontrol_on>=\\Q3
   <hwflowcontrol_off>=\\Q0
   <compression_on>=%C1
   <compression_off>=%C0
   <autodial_on>=ATDT
   <autodial_off>=ATD

   COMMAND_INIT=AT&F&C1&D2&N0 W1 V1 \\J0 S0=0 S2=128 S7=55<cr>
   COMMAND_INIT=AT<hwflowcontrol><protocol><compression><speaker><cr>
   COMMAND_DIAL=<autodial><phonenumber><cr>
   CONNECT=<cr><lf>CONNECT <carrierbps><cr><lf>
   COMMAND_LISTEN=ATS0=1<cr>
   CONNECT=<cr><lf>CONNECT <carrierbps><cr><lf>
 