WinNT Err Msg: Error 614 Out of Buffers When Using RAS Script

ID: Q123597


The information in this article applies to:
  • Microsoft Windows NT Workstation version 4.0
  • Microsoft Windows NT Server version 4.0
  • Microsoft Windows NT Server version 4.0, Terminal Server Edition


SYMPTOMS

When you use a script to automatically log on to your dial-up service, if the server fails to respond to the script prompts, the script may stop responding (hang). After you quit the script that has stopped responding and attempt to redial the connection, you may receive one of the following error messages:

Error 614 - Out of buffers.
-OR-
Error 203 - The system could not find the environment option that was entered.


RESOLUTION

To resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, please see the following article in the Microsoft Knowledge Base:

Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack


STATUS

Microsoft has confirmed this to be a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.

Additional query words: modem

Keywords : kberrmsg kbnetwork NT4SP4Fix ntras kbbug4.00 kbfix4.00.sp4 NTSrvWkst
Version : WinNT:4.0
Platform : winnt
Issue type : kbbug


Last Reviewed: April 10, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.