The information in this article applies to:
SYMPTOMS
When using Equinox Systems intelligent serial board and driver, the Win16
subsystem fails when a 16-bit terminal application is run. Example programs
of this type are WinCim and Procomm Plus for Windows.
Then, the 16-bit application and the Win16 subsystem terminate. However, Windows NT does not fail. CAUSE
The Win16 subsystem is not correctly dealing with overlapped reads when
communicating with the COM ports.
STATUS
Microsoft has confirmed this to be a problem in Windows NT Workstation and
Windows NT Server version 3.5. This problem was corrected in the latest
U.S. Service Pack for Windows NT version 3.5. For information on obtaining
the Service Pack, query on the following word in the Microsoft Knowledge
Base (without the spaces):
The products included here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability. Additional query words: prodnt
Keywords : ntdriver nt16ap |
Last Reviewed: February 24, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |