RAS Error Message: "Error 1: Incorrect Function"
ID: Q129283
|
The information in this article applies to:
-
Microsoft Windows NT Workstation version 3.5
-
Microsoft Windows NT Server version 3.5
SYMPTOMS
When you attempt to use the Windows NT 3.5 Remote Access client
(RASPHONE.EXE) to connect to a RAS server, the following error appears:
Error Connecting To <servername>
Error 1: Incorrect Function
Press F1 for more information
where <servername> is the name of the RAS server that you are attempting to
connect to.
CAUSE
This error message appears when you incorrectly install Microsoft Windows
NT 3.5 U.S. Service Pack 2.
Steps to Reproduce Problem
- Download the Intel 3.5-inch Disk Set for Service Pack 2. This set
includes the following nine self-extracting executables:
RUNME.EXE
SP231.EXE
SP232.EXE
SP233.EXE
SP234.EXE
SP235.EXE
SP236.EXE
SP237.EXE
SP238.EXE
- Extract each of the nine into a directory on your hard disk drive.
- Run UPDATE.EXE from that directory to install Service Pack 2.
NOTE: You may receive error messages when attempting to copy the
following files:
OEMNSVSM.INF
OEMNXPTC.INF
VIDEO.INF
- When the update program prompts you to restart Windows NT, choose
ignore to continue the installation. These files are copied to the
%SYSTEMROOT%\SYSTEM32 directory, despite the error message.
- Attempt to use RASPHONE to connect to a RAS server.
You receive the error message noted above.
RESOLUTION
To successfully use RAS to dial into a RAS server, do one of the following:
- Use the MAKE35.BAT file to create a disk set for Service Pack 2. After
you have created the eight Service Pack 2 disks using MAKE35.BAT,
run UPDATE.EXE from Disk 1 and follow the prompts to complete the
installation of Service Pack 2.
-or-
- Run Control Panel, choose Network, remove RAS, and then reinstall RAS.
When you are prompted for media during the reinstall, provide your
original Windows NT 3.5 CD-ROM or floppy disks.
This load the pre-Service Pack 2 RAS files. As soon as possible,
reinstall Service Pack 2 using the correct procedure to update the RAS
files.
Additional query words:
prodnt
Keywords :
Version :
Platform :
Issue type :