Event Error 2022: Server Unable to Find a Free Connection
ID: Q130922
|
The information in this article applies to:
-
Microsoft Windows NT Advanced Server version 3.1
-
Microsoft Windows for Workgroups version 3.11
NOTE: The information in this article does not apply to Windows NT 3.5,
3.51, or 4.0. Do not use the workaround below.
SYMPTOMS
After you share a Gateway Service for NetWare (GSNW) session, the
following event log appears in the Event Viewer when a Windows for
Workgroups version 3.11 client computer attempts to connect to the Windows
NT server share:
Event ID: 2022
Source: SRV
Type: Error
Description: The server was unable to find a free connection
<number> times in the last <seconds> seconds.
WORKAROUND
To work around this problem, you can modify the registry.
WARNING: Using Registry Editor incorrectly can cause serious, system-wide
problems that may require you to reinstall Windows NT to correct them.
Microsoft cannot guarantee that any problems resulting from the use of
Registry Editor can be solved. Use this tool at your own risk.
- Run the Registry Editor (Regedt32.exe).
- From the HKEY_LOCAL_MACHINE subtree, go to the following subkey:
\SYSTEM\CurrentControlSet\Services\LanmanServer\Parameters
- On the Edit menu, click Add Value.
- Add the following:
Value Name: MaxFreeConnections
Data Type: REG_DWORD
Data: 8
Value Name: MaxWorkItems
Data Type: REG_DWORD
Data: 255
NOTE: The maximum number for Work Items is 512. You should use
255 first, and then increase it as needed, up to a maximum of 512.
- Quit Registry Editor.
- Shut down and restart Windows NT.
Additional query words:
3.1 3.11 wfw gsnw nwcs
Keywords : kbinterop kbnetwork NTInterop ntnetserv NTSrv