The information in this article applies to:
SYMPTOMS
If you send a print job from a computer running Windows NT 3.5 Server to a
LocalTalk-connected print device on the far side of a LocalTalk bridge, the
job does not print correctly. Instead, the job is truncated and a
PostScript IOError message appears on an additional page.
CAUSE
The Windows NT 3.5 Services For Macintosh print monitor (SFMMON.DLL) fails
to set the EOM bit after sending the last frame of print job data, before
sending the Close Connection Request.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.5.
This problem was corrected in Windows NT Server version 3.51.
Additional query words: prodnt end of message I/o
Keywords : ntmac ntnetserv ntprint NTSrv |
Last Reviewed: February 25, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |