The information in this article applies to:
SYMPTOMS
Installation of Windows NT 3.5 on a Quantum Empire hard drive connected to
an Adaptec controller fails with the following STOP Message:
CAUSE
The STOP Message occurs because the Adaptec controller is configured for a
maximum synchronous transfer rate (Max Sync Xfer Rate) of 10 MB (megabytes)
per second. According to Quantum technical support, the error is due to the
clock on the Adaptec controller that allows the adapter to negotiate a Max
Sync Xfer Rate of 10.6 MB/sec. The digital filter on the hard drive returns
an error to the operating system because it is set for a Max Sync Xfer
Rate of 10.2 MB/sec.
WORKAROUND
There is updated firmware for the Quantum Empire drive which fools the SCSI
controller into a connection of 8 MB/sec. when it is set for 10 MB/sec. The
firmware upgrade may be obtained from Quantum by calling their technical
support line at (800) 826-8022.
Additional query words: prodnt 3.5 disk hang complete 2100S
Keywords : nthw |