SYMPTOMS
When you boot Windows NT on an NEC Versa P-75 or M-75 Laptop, event Id 7026
is written to the system log. A service fails to start. Using Event view to
view Event Id 7026 shows:
CAUSE
This problem occurs when you turn off the PCMCIA power option in the auto
setup power management menu. This disables the PCMCIA Bus. Consequently,
none of the PC Cards work and the PCMCIA driver fails to load during
startup.
RESOLUTION
To resolve this problem, enable PCMCIA power on the Versa:
NOTE: Although Windows NT 3.51 does not support power management features built into the BIOS, this power management option must be enabled to support the PC Cards in the computer. Additional query words: pmccia vendor nec versa prodnt