STOP 0x7A with Adaptec 2740A SCSI and 3Com Etherlink III

ID: Q133183


The information in this article applies to:
  • Microsoft Windows NT Workstation version 3.51
  • Microsoft Windows NT Server version 3.51


SUMMARY

When you use an Adaptec 2740A SCSI controller and a 3Com Etherlink III network interface card (NIC) in Windows NT 3.51, the following error message appears:

STOP: 0x0000007a (0x00000103, 0xC0000185, 0x00000000, 0x00043000)
Kernel_Data_Inpage_Error
CPU ID:Genuine Intel 5.2.5 IRQ1:1F Sys Version:0xF0000327


CAUSE

This problem occurs if the Adaptec 2740A SCSI controller and the 3Com Etherlink III NIC are using the same IRQ. The Adaptec 2740A SCSI controller uses a default IRQ of 10.


RESOLUTION

To correct this problem, configure the IRQ of the 3Com Etherlink III NIC or the Adaptec 2940A SCSI controller to another, unused IRQ.

The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words: trap 7A elnkiii

Keywords :
Version :
Platform :
Issue type :


Last Reviewed: February 16, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.