Thomas Conrad Token Ring cards TC-4045 and TC 4145 Setup Problem

ID: Q134761


The information in this article applies to:
  • Microsoft Windows NT Workstation version 3.51
  • Microsoft Windows NT Server version 3.51


SYMPTOMS

When you install Windows NT 3.51 on your non-PCI bus computer that has a TC- 4045 or TC-4145 network card installed, one or more of the following symptoms occur:

  • Your computer hangs during Windows NT Setup.


  • A message appears after Setup that the network could not start.


  • The System Log contains the following event after Setup:
    5004: TC4045 could not connect to interrupt number supplied.


  • Your floppy drive does not work.



CAUSE

The OEMSETUP.INF file assumes that your TC-4045 or TC-4145 network card is installed a PCI bus, however, it should ask you to specify what type of bus (ISA, EISA, PCI, MCA) the card is installed in.


RESOLUTION

Thomas Conrad has a new OEMSETUP.INF file. To obtain this file, download the self-extracting NT351OEM.EXE file from the Thomas Conrad BBS, WEB server, or the CompuServe Thomas Conrad forum. For more information contact Thomas Conrad at:

  • BBS phone number: (512) 433-6156


  • WEB site address: WWW.TCI.COM


  • CompuServe forum: GO TCCForum


Additional query words: prodnt

Keywords : kb3rdparty kbsetup ntsetup ntdriver kbbug3.51
Version : 3.51
Platform : winnt
Issue type :


Last Reviewed: January 15, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.