SYMPTOMS
If you use the Executive Software Diskeeper 1.0 uninstall feature after you
upgrade Windows NT 3.5 to 3.51 and restart your computer, you receive an
entry point error in NTDLL.DLL and Windows NT hangs and becomes unbootable.
CAUSE
Diskeeper version 1.0 is not designed to run under Windows NT 3.51.
RESOLUTION
Run the emergency repair disk (ERD) to recover your Windows NT 3.51 boot
and system files. Do not run Diskeeper version 1.0 under Windows NT 3.51.
Compuserve- GO EXECSOFT MORE INFORMATION
This problem can also occur in NT 4.0 server and workstation. It
is strongly recommended that customers read the Product Alert on ExecSoft[ASCII 146]s
web site which is located at http://www.execsoft.com/pas/pa091796.htm. Executive Software Diskeeper is manufactured by Executive Software, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability. Additional query words: prodnt defrag utility defragmenter