STOP Msg: 0x0000007B Installing Windows NT on HP Vectra XU/XUC

ID: Q137860


The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5, 3.51
  • Microsoft Windows NT Server versions 3.5, 3.51


SYMPTOMS

When you install Windows NT 3.5 or 3.51 on a Hewlett-Packard (HP) Vectra XU/XUC P5 Pentium-based computer using an on-board AMD SCSI controller, the following STOP Message appears after Setup completes the mass storage device detection and reboots your computer:

STOP: 0x0000007B
INACCESSIBLE_BOOT_DEVICE


RESOLUTION

To correct this problem:

  1. Ensure the BIOS version of your Vectra computer is 5.08 or above. If it is not, contact HP Vectra DeskTop Support at (970) 635-1000 for a BIOS update.


  2. Obtain VJS2NIUS.EXE, which contains a new AMD SCSI controller driver AMSINT.SYS, from the HP Bulletin Board Service at (208) 344-1691 or HP's web site at http://www.hp.com. Extract VJS2NIUS.EXE on another computer.


  3. Run Windows NT Setup by typing the following (which creates the Windows NT Setup floppy disks):

    WINNT /OX

    -or-

    WINNT32 /OX


  4. Replace the AMSINT.SYS driver on the third Windows NT Setup floppy disk with the SCSI driver obtained from HP (Step 2 above).


  5. Continue Windows NT Setup.


Additional query words: trap 0x7b blue hang

Keywords : ntdriver nthw
Version : 3.50 3.51
Platform : WINDOWS
Issue type :


Last Reviewed: January 21, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.