InitiateSystemShutdown API Ignores Timed Delay

ID: Q140377


The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5, 3.51
  • Microsoft Windows NT Server versions 3.5, 3.51


SYMPTOMS

If an application attempts to shutdown or reboot a Windows NT system using the InitiateSystemShutdown API, the time delay passed to the target system is ignored if that system has been locked by the current user. The target system shuts down or reboots immediately. If the target system has not been locked the time delay is honored and it shuts down or reboots as expected.


STATUS

Microsoft has confirmed this to be a problem in Windows NT versions 3.5 and 3.51. This problem was corrected in Windows NT Workstation and Server version 4.0.

Additional query words: prodnt

Keywords : ntsecurity NTSrvWkst
Version : 3.50 3.51
Platform : WINDOWS
Issue type :


Last Reviewed: January 30, 1999