The information in this article applies to:
SYMPTOMS
When you attempt to access a magneto optical drive in Windows NT, the
following error message appears:
The drive is recognized during the boot sequence; however, Windows NT is not able to determine the file structure of the media when accessing the drive. CAUSEThis problem occurs if the magneto optical drive has been formatted using the Adaptec EZ-SCSI or CorelSCSI format utilities in DOS. WORKAROUND
To work around this problem, do one of the following:
STATUSMicrosoft has confirmed this to be a problem in Windows NT versions 3.5 and 3.51. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available. MORE INFORMATIONIn Windows NT, removable drives are recommended to use one partition. This means that sector zero on the drive must be a Master Boot Record (MBR). In DOS, removable drives can be formatted this way or as a floppy drive (this means that sector zero contains a BIOS Parameter Block for the file system). The Adaptec EZ-SCSI and CorelSCSCI utilities format the removable drives as floppies. Windows NT currently does not support this format. Additional query words: prodnt fat ntfs
Keywords : nthw ntfilesys |
Last Reviewed: February 9, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |