Dr. Watson Error Installing Internet Information Server

ID: Q148714


The information in this article applies to:
  • Microsoft Internet Information Server version 1.0
  • Microsoft Windows NT Server version 3.51


SYMPTOMS

When you install the Internet Information Server on a Windows NT Server that has the Banyan Vines Client for NT installed, a Dr. Watson Exception error message appears.


WORKAROUND

To work around this problem:

  1. Remove the Banyon Vines client software. Use the command "setup/uninstall" (without quotes) from the Banyan Vines Client for NT distribution media.


  2. Restart Windows NT Server.


  3. Install the TCP/IP protocol in Control Panel Network.


  4. Restart Windows NT Server.


  5. Make sure that the TCP/IP protocol is working properly. Use the TCP/IP connectivity utilties, such as Ping, FTP and Telnet.


  6. If the TCP/IP protocol is working properly, install the Internet Information Server.



STATUS

Microsoft has confirmed this to be a problem in Windows NT version 3.51. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

Additional query words: prodnt 1.00 3.51 winnt

Keywords : iisinterop iissetup
Version : 1.00
Platform : WINDOWS
Issue type :


Last Reviewed: February 12, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.