The information in this article applies to:
SYMPTOMS
If HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\Lsa\CrashOnAuditFail
is enabled in the registry, and Auditing of ProcessTracking is turned on,
then during shutdown the system will always fail with a Stop error message
reading:
For additional information, please see the following article in the Microsoft Knowledge Base: ARTICLE-ID: Q140058 CAUSEThe failure occurs because an attempt is made to log the termination of a process after the event-logging service has already been shut down. Therefore, audit logging fails, and the blue screen is generated. RESOLUTION
To resolve this problem, upgrade to Windows NT Workstation and Server
version 4.0 or install the fix mentioned below.
STATUS
Microsoft has confirmed this to be a problem in Windows NT 3.5 and 3.51.
This problem was corrected in Windows NT Workstation or Server version 4.0.
This problem was corrected in the latest Windows NT 3.51 U.S. Service
Pack. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K Additional query words: usermgr security
Keywords : kbnetwork ntsecurity kbbug3.50 kbbug3.51 NTSrvWkst |