Restoring the UPS Tool and Icon in Control Panel

ID: Q150541


The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.5, 3.51
  • Microsoft Windows NT Server versions 3.5, 3.51


SUMMARY

When you install Powershute software from American Power Conversion (APC) on a Windows NT computer, the uninterruptable power supply (UPS) icon in Control Panel is replaced with an icon from APC.


MORE INFORMATION

APC supplies Remove.exe to remove the APC program and icon. The Windows NT UPS tool and icon are not restored. To restore the UPS tool and icon, perform the following steps;

  1. Run the Remove.exe program to remove the Powershute software.


  2. Expand the UPS.CP_ file from the Windows NT CD and copy it to the %SystemRoot%\System32 directory. This step is necessary even if the file is currently on the hard disk drive, because the Powershute software file needs to be replaced.


  3. WARNING: Using Registry Editor incorrectly can cause serious, system-wide problems that may require you to reinstall Windows NT to correct them. Microsoft cannot guarantee that any problems resulting from the use of Registry Editor can be solved. Use this tool at your own risk.
  4. Save the following registry key to disk:


  5. 
    HKEY_USER\DEFAULT\Control Panel\Cache\UPS.CPL
    
    File Size: REG_DWORD: 0x5f10
    
        High File Time:  REG_DWORD: 0x1ba2b78
        Low File Time: REG_DWORD: 0x570f300
        Module Path: REG_SZ: %systemroot%\System32\UPS.CPL
        Number Applets: REG_DWORD: 0x1
    
        Subkey: 0
            Applet Data: REG_DWORD: 0x64
            Applet Full Name: REG_SZ: &UPS
            Applet Name: REG_SZ: UPS
            Color Info: REG_BINARY:  00000000...
            Description:  REG_SZ: Configures the Uninterruptible Power Supply
            Help Context: REG_DWORD: 0x1450
            Help File: REG_SZ: control.hlp
            Icon Color: REG_BINARY: 00 00 00 00 00 00 00 00...
            Icon Mask:  REG_BINARY : ff ff ff ff ff ff ff ff...
            IconX:  REG_DWORD: 0x10
            IconY:  REG_DWORD: 0x10
            Mask Info: REG_BINARY: 00 00 00 00 20 00 00 00...
     
  6. Add a UPS.CPL key to the following locations and restore the saved key to these new locations. The following parameters are the defaults.



HKEY_CURRENT_USER\Control Panel\Cache
HKEY_USER\"sid number"\Control Panel\Cache

    File Size: REG_DWORD: 0x5f10
    High File Time:  REG_DWORD: 0x1ba2b78
    Low File Time: REG_DWORD: 0x570f300
    Module Path: REG_SZ: %systemroot%\System32\UPS.CPL
    Number Applets: REG_DWORD: 0x1

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\UPS

ErrorControl: REG_DWORD: 0x1

    ImagePath: REG_EXPAND: %systemroot%\System32\ups.exe
    ObjectName: REG_SZ: LocalSystem
    Start: REG_DWORD: 0x3
    Type: REG_DEWORD: 0x10 


Replace:American Power Conversion can be contacted at (800) 800-4272.

The Powershute software discussed here is manufactured by Amerian Power Conversion, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words: prodnt APC

Keywords : NTSrv ntutil
Version : 3.50 3.51
Platform : WINDOWS
Issue type :


Last Reviewed: February 17, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.