The information in this article applies to:
SYMPTOMS
Windows NT may stop responding on shutdown and/or the following message may
appear:
CAUSE
The service controller issues an asynchronous TransactNamedPipe and asks it
to read four bytes to a stack variable. It then waits two minutes for the
TransactNamedPipe to finish. After two minutes it returns from the function
without canceling the operation. When the operation finishes it overwrites
the stack. RESOLUTIONThe I/O operation is canceled before the function returns. STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51.
This problem was corrected in the latest Windows NT 3.51 U.S. Service
Pack. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K Additional query words: 3.51 prodnt EMS hung
Keywords : ntnetserv NTSrv |
Last Reviewed: February 20, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |