The information in this article applies to:
SYMPTOMSIf you have a server with more than eight network interfaces installed and you use the Network Segment object in Performance Monitor to monitor all your network interfaces, you are only able to monitor the first eight bound interfaces. CAUSEThere is a hard-coded limit of eight supported Network Segment interfaces in the Netmon performance counter DLL. RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, please see the following article in the
Microsoft Knowledge Base: Q152734 How to Obtain the Latest Windows NT 4.0 Service Pack NOTE: This hotfix supports monitoring a maximum of 16 interfaces on one computer. STATUSMicrosoft has confirmed this to be a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4. Additional query words: 4.00 bh perfmon
Keywords : kbenv kbtool NT4SP4Fix kbbug4.00 kbfix4.00.sp4 NTSrv ntutil |
Last Reviewed: April 10, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |