RPC Sample File Helloc.exe Requires Full Redirector
ID: Q162785
|
The information in this article applies to:
-
Microsoft Network Client for MS-DOS version 3.0
-
Microsoft Win32 Software Development Kit (SDK)
on the following platforms: Win95
-
Microsoft Win32 Software Development Kit (SDK) for Windows NT
SYMPTOMS
If run from Microsoft Network Client 3.0, the RPC client sample file
Helloc.exe fails with the following or a similar message:
RpcStringBindingCompose returned 0x0
pszStringBinding = ncacn_np:rxobot_serv[\\pipe\\hello]
RpcBindingFromStringBinding returned 0x0
Rpc Binding Handle = 3e5a0016
Calling the remote procedure 'HelloProc'
Print the string 'hello, world' on the server
Runtime reported exception 0x1b = 27
RpcStringFree returned 0x0
RpcBindingFree returned 0x0
CAUSE
Either the Network Client is running the Basic Redirector, or the logged on
user cannot connect to the IPC$ directory on the server.
RESOLUTION
To resolve this problem, do either of the following:
- Run SETUP on the client and configure it to run the Full Redirector.
-or-
- Make sure that the user who is logged on at the client can perform the
following operation:
NET USE \\<server>\IPC$
NOTE: It is not necessary to make an IPC$ connection before running
Helloc.exe, but Helloc.exe will fail if either the client or the user
is not capable of making an IPC$ connection.
Additional query words:
prodnt
Keywords : ntdosap
Version : MS-DOS:3.0; NT:; WINDOWS:
Platform : MS-DOS NT WINDOWS
Issue type :