Zip Cartridges Formatted in LBA Mode are Unreadable

ID: Q168293


The information in this article applies to:
  • Microsoft Windows NT Workstation versions 3.51, 4.0
  • Microsoft Windows NT Server versions 3.51, 4.0


SYMPTOMS

When you use an Iomega Zip IDE Insider drive to re-partition and reformat a Zip cartridge using LBA mode, the cartridge will be unreadable from other SCSI, Parallel, IDE Zip drives (operating in non-LBA mode), or ATAPI Zip drives.


CAUSE

The standard translated geometry for all Zip drives is 512 cylinders, 12 heads, and 32 sectors per track. LBA translation of the drive geometry results in a translated geometry of 97 cylinders, 32 heads, and 63 sectors per track. Zip drives using standard Zip disk geometry will be unable to read the alternate disk geometry presented by Zip cartridges formatted under LBA mode.


RESOLUTION

In the computer's CMOS setup, disable LBA translation on the Zip IDE Insider drive. Enter the correct cylinder, head, and sector information, as indicated above.


MORE INFORMATION

The third-party products discussed here are manufactured by vendors independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability.

Additional query words: Iomega IDE Insider removable Zip

Keywords : kb3rdparty kbhw kbsetup ntsetup nthw NTSrvWkst
Version : WinNT:4.0
Platform : winnt
Issue type :


Last Reviewed: February 16, 1999