The information in this article applies to:
SYMPTOMS
When you connect to a computer running Windows NT Server from a computer
running Windows NT Workstation using Remotely Possible/32 and perform
various tasks, such as launching Task Manager or Cheyenne ARCserve, the
computer running Windows NT Server crashes with the following error
message:
CAUSERemotely Possible software has some incompatibility with Floating Point Emulation software. If the system board is using the faulty floating point error Pentium processor and you have floating point emulation enabled, your system may trap. WORKAROUND
Disable the floating-point emulation by using the Pentnt.exe utility
shipped with Windows NT.
Keywords : nt32ap NTSrvWkst |
Last Reviewed: January 19, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |