The information in this article applies to:
SYMPTOMSWMI will go into an infinite loop when an attempt is made to connect to an HP-UX 9.x system running DCE. The customer will be unaware of this loop except that WMI will hang, and that there is constant network traffic between the systems until the Windows NT system is restarted. CAUSEThe implementation of RPC used in HP-UX 9.x does not handle connections correctly. In the endless loop case, the remote server returns NCA_STATUS_UNK_IF(0x1C010003). HP-UX 9.x's RPC implementation is incorrect. Specifically they are not byte-swapping the TimeHiAndVersion field of the Activity UUID. Because of this, MSRPC does not recognize the datagram reject packet. This has been resolved in HP-UX 10. RESOLUTION
A supported fix that corrects this problem is now available from Microsoft,
but has not been fully regression tested and should be applied only to
systems experiencing this specific problem. If you are not severely
affected by this specific problem, Microsoft recommends that you wait for
the next Windows NT service pack that contains this fix.
http://support.microsoft.com/support/supportnet/default.aspThe English version of this fix should have the following file attributes or later:
NOTE: If you contact Microsoft to obtain this fix, a fee may be charged. This fee is refundable if it is determined that you only require the fix you requested. However, this fee is non-refundable if you request additional technical support. For more information about eligibility for no-charge technical support, see the following article in the Microsoft Knowledge Base: Q154871 Determining If Your Product Is Eligible for No-Charge Technical Support STATUSMicrosoft has confirmed this to be a problem in Windows NT version 4.0. Additional query words: 4.00
Keywords : kbbug4.00 kbfix4.00 |