NetBEUI Data Transfer Hangs on Intergraph Workstation

ID: Q200815


The information in this article applies to:
  • Microsoft Windows NT Server version 4.0
  • Microsoft Windows NT Workstation version 4.0


SYMPTOMS

NOTE: The information in this article applies to Windows NT 4.0 on an Intergraph TD300 150-MHz single-x86-processor workstation with an onboard AMD PCNET PCI Ethernet network adapter.

When a program fills between 50 and 100 percent of physical memory and a large file is copied from the computer to a network client, the NetBEUI stack may stop responding (hang). When this occurs, the following symptoms may also occur:

  • The file-copy process stops.


  • Microsoft Windows 95 network clients are unable to connect to the computer.


  • No outbound connections can be made to network clients from the computer.


  • Event ID 9011 is generated on the server.



CAUSE

The AMD PCNET PCI Ethernet network adapter driver that is included with Windows NT 4.0 causes this problem.


RESOLUTION

To resolve this issue, obtain the current driver from the Intergraph Web site:

http://www.intergraph.com
The third-party contact information included in this article is provided to help you find the technical support you need. This contact information is subject to change without notice. Microsoft in no way guarantees the accuracy of this third-party contact information.


MORE INFORMATION

The following event is a sample event that may be generated by this behavior:


6/19/98  5:06:37 PM  Nbf  Information  None  9011  N/A  <ServerName>
The description for Event ID ( 9011 ) in Source ( Nbf ) could not be found.
It contains the following insertion string(s): 
\Device\Nbf_AMDPCN1, Nbf, FRMR. 

Additional query words: freeze

Keywords : kb3rdparty kbnetwork kbbug4.00
Version : winnt:4.0
Platform : winnt
Issue type : kbprb


Last Reviewed: September 10, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.