Event ID 2022 Occurs When Norton Speed Disk and Norton AutoProtect Service Are in Use

ID: Q250264


The information in this article applies to:
  • Microsoft Windows NT Server version 4.0


SYMPTOMS

When you are using Microsoft Windows NT Server 4.0, the primary domain controller (PDC) may randomly stop responding (hang). Event Viewer records the following event:

Event ID: 2022
Source: SRV
Type: Error
Description: The server was unable to find a free connection [number] times in the last [seconds] seconds.


CAUSE

This behavior can occur when you are using Symantec's Norton Speed Disk and Norton AntiVirus AutoProtect services.


RESOLUTION

To work around this behavior, disable the Norton Speed Disk and Norton AutoProtect services, and then restart the server.

Additional query words:

Keywords :
Version : winnt:4.0
Platform : winnt
Issue type : kbprb


Last Reviewed: January 5, 2000
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.