NETWORKS.WRI from Windows for Workgroups 3.11 (Part 2 of 4)
ID: Q109501
|
The information in this article applies to:
-
Microsoft Windows for Workgroups version 3.11
SUMMARY
The following information was taken from the Microsoft Windows for
Workgroups version 3.11 NETWORKS.WRI file.
MORE INFORMATION
2.2 More Information about Using Novell NetWare with Windows for
Workgroups 3.11
- When you set up NetWare support in Windows for Workgroups, the
value of the lastdrive command in your CONFIG.SYS file is set to P.
When you restart your computer, your login directory is drive Q. If
you have any NetWare login scripts, make sure they reference the
correct drive letter for your login directory.
When the lastdrive command is set to P, you can use letters from A to
P to connect to other Windows for Workgroups computers or Windows NT
or Microsoft LAN Manager servers. Letters after P are reserved for
connecting to Novell NetWare servers.
- Do not try to log in, log out, attach, or detach a Novell server
from MS-DOS Prompt within Windows. You should log in before you start
Windows for Workgroups, and attach or detach servers by using File
Manager or Print Manager.
- When you set up NetWare support in Windows for Workgroups for
IPXODI.COM and LSL.COM, Setup adds the odihlp command to your
AUTOEXEC.BAT file. It inserts it on the line following the ipxodi
command. Do not change the order of these lines.
- If you are using a token-ring network and the driver on your Novell
server does not support source routing (for example, IBM token-ring
drivers earlier than version 2.4), remove the ROUTE.COM statement
from your AUTOEXEC.BAT file.
- If you have problems connecting to a Novell server, make sure the
Adapter Media Type setting in Network Setup matches your Novell
NetWare software configuration. For more information, see Appendix C,
"Troubleshooting," in The Microsoft Workgroup Add-On "User's Guide."
- By default, NetWare allows you access to only 40 files at a time.
When you are running applications with Windows, you can exceed this
limit rather quickly. If you do, you might see unexpected error
messages. To increase the file access limit, add the following line
to the beginning of your NET.CFG file:
file handles=60
You should also add the following to your CONFIG.SYS file:
files=60
- If you get unusable output (such as incorrect fonts, garbled text,
invalid page breaks, or blank lines) when you try to print to a
NetWare server, you may need to edit your print-job configuration.
Try using the NetWare PRINTCON utility to set the Auto Endcap and
Enable Timeout options to No.
- Swapping to a drive on a NetWare 286 server might make starting
Windows for Workgroups take up to a minute. For information about
controlling the location of your swap file, see Chapter 11, "Managing
Memory and Performance," in the Microsoft Windows for Workgroups
"User's Guide."
- A NetWare file server does not include the directory entries dot
(.) and double dot (..) as MS-DOS does. However, the NetWare shell
(version 3.01 or later) can emulate these entries when applications
attempt to list the files in a directory. If you have problems
listing files or deleting directories, turn on the Show Dots feature.
To do this, add the following line to the beginning of your NET.CFG
file:
show dots=on
Turning on Show Dots will cause problems with earlier versions of
some 80286-based NetWare utilities, such as BINDFIX.EXE and
MAKEUSER.EXE. Make sure you upgrade these utilities if you upgrade
your NetWare shell. For more information, contact your Novell dealer.
- Redirected drives can look different in Windows for Workgroups than
without Windows for Workgroups. For example, a device mapped as
FileServerName/Volume:Directory will appear in Windows as
FileServerName/Volume:\, showing the root of the file server's shared
volume rather than the subdirectory. You can correct this with the
MAP ROOT entry, as explained in the following information.
- In some cases, Windows-based applications may change the default
directory on a drive. This might cause problems if, for example, your
path includes the current directory on a network drive (that is, your
path includes a drive letter without a specific directory, such as z:
instead of z:\system).
You can prevent this problem by using MAP.EXE and LOGIN.EXE versions
3.0 and later to set up false roots, or by choosing the MAP ROOT
function when you are mapping a connection in File Manager. This
feature simulates the MS-DOS subst command, which sets the root of a
given drive to a directory designated by the user instead of to the
true root of the volume.
For example, suppose you normally mapped drive F to the HOME\TERRI
directory on the SERVER\SYS volume, and then included F: in your
path. You would do this by including the following command in your
AUTOEXEC.BAT file or by typing the command before you start Windows:
map f:=server\sys:home\terri
The default directory on drive F would then be HOME\TERRI. To prevent
Windows from changing this, you would replace that command with the
following:
map root f:=server\sys:home\terri
This command would make the directory HOME\TERRI appear to be the
root of drive F.
- You can adjust the way Windows handles your network drive mappings
by using the Network option in Control Panel.
Usually, when you quit Windows for Workgroups, all of your drive
mappings are restored to the way they were before you started Windows
for Workgroups, and all changes you made while running Windows are
lost. If you clear the Restore Drives option in the settings dialog
box for NetWare, the mappings you made in Windows for Workgroups will
remain when you quit.
Typically, each instance of MS-DOS Prompt you start from Windows for
Workgroups has its own set of drive mappings. Changes you make in one
instance do not affect another. If you set the NWShareHandles option,
drive mappings will instead be global, and changes to the mappings or
the current drive made in one instance of MS-DOS Prompt will affect
all other applications. If you are running a NetWare 286 server,
setting NWShareHandles increases the number of workstations that can
be connected to the server before the server runs out of available
connections.
See the Help available in the Network dialog box in Control Panel for
more information on these options.
- If you have applications or files that use extended characters
(ASCII characters above 128) and you have problems viewing or using
them, try adding the following line to your NET.CFG file:
special uppercase = on
- When you connect or disconnect network resources from File Manager,
Print Manager, or Control Panel, pay attention to the state of the
Permanent check box. If this option is selected when you make a
connection, the connection is automatically made each time you
restart Windows for Workgroups. To stop reconnecting, disconnect from
the network resource with the Permanent check box selected. If the
option is not selected when you disconnect, the connection is removed
for the current Windows session but is reconnected when you restart
Windows for Workgroups.
- If you were running Novell NetBIOS before you set up Windows for
Workgroups, the Setup program attempts to remove it. We do not
recommend using the Novell NetBIOS protocol. Instead, use the IPX/SPX
protocol that is compatible with NetBIOS.
To install the IPX/SPX protocol that is compatible with NetBIOS:
1. In the Networks group, choose the Network Setup icon.
2. In the Network Setup dialog box, choose the Drivers button. The
Network Drivers dialog box appears.
3. Choose the Add Protocol button. The Add Network Protocol dialog
box appears.
4. Choose "IPX/SPX Compatible Transport with NetBIOS" from the drop
down list box. Then choose OK.
2.3 Changes to System Files
The following sections describe the changes that Setup makes to your
system files when you set up Windows for Workgroups 3.11 with these
common configurations.
2.3.1 IPXODI.COM and LSL.COM support over Ethernet or Token Ring Networks
When you install Windows for Workgroups 3.11 with IPXODI.COM and
LSL.COM support, the following lines are added to your SYSTEM.INI
file:
[386Enh]
network=*vnetbios,*vwc,vnetsup.386,vredir.386,vserver.386
transport=nwlink.386,nwnblink.386,netbeui.386
secondnet=vnetware.386, vipx.386
netmisc=ndis.386,msodisup.386
netcard=
InDOSPolling=FALSE
netcard3=
OverlappedIO=Off
[network]
multinet=netware3
winnet=wfwnet/00025100
[NetWare]
NWShareHandles=FALSE
RestoreDrives=TRUE
[network drivers]
netcard=
transport=
devdir=C:\WINDOWS
LoadRMDrivers=No
[NWNBLINK]
LANABASE=1
The following sample PROTOCOL.INI file is for a computer that
contains a DEC Etherworks Turbo/TP Ethernet Network Adapter.
Bold lines designate lines specific to this network adapter and its
configuration.
NOTE: When using Novell's ODI drivers, the "BINDINGS=" should equal
the Novell MLID name.
[network.setup]
version=0x3110
netcard=ms$ewtrbtp,1,MS$EWTRBTP,4
transport=ms$nwlinknb,NWLINK
transport=ms$netbeui,NETBEUI
lana0=ms$ewtrbtp,1,ms$netbeui
lana1=ms$ewtrbtp,1,ms$nwlinknb
[net.cfg]
PATH=C:\NOVELL\net.cfg
[MS$EWTRBTP]
[Link Driver DEPCA]
Frame Ethernet_SNAP
Frame Ethernet_802.2
Frame Ethernet_II
Frame Ethernet_802.3
[NWLINK]
BINDINGS=DEPCA
[NETBEUI]
BINDINGS=DEPCA
LANABASE=0
SESSIONS=10
NCBS=12
The following sample PROTOCOL.INI file is for a computer that
contains a IBM Token Ring 16/4 Network Adapter.
Bold lines designate lines specific to this network adapter and its
configuration.
NOTE: When using Novell's ODI drivers, the "BINDINGS=" should equal
the Novell MLID name.)
[network.setup]
version=0x3110
netcard=ms$ibmtr4,1,MS$IBMTR4,4
transport=ms$nwlinknb,NWLINK
transport=ms$netbeui,NETBEUI
lana0=ms$ibmtr4,1,ms$netbeui
lana1=ms$ibmtr4,1,ms$nwlinknb
[net.cfg]
PATH=C:\NOVELL\net.cfg
[MS$IBMTR4]
[Link Driver TOKEN]
Frame Token-Ring
Link Driver TOKEN
[NWLINK]
BINDINGS=TOKEN
[NETBEUI]
BINDINGS=TOKEN
LANABASE=0
SESSIONS=10
NCBS=12
The following sample NET.CFG is for a computer with a DEC Etherworks
Turbo/TP Ethernet Network Adapter. You may need additional entries in
your NET.CFG file, depending on the way your network is set up.
Lines shown here in bold type are added when you install Windows for
Workgroups 3.11.
SHOW DOTS=ON
FILE HANDLES=60
Link Driver DEPCA
Frame Ethernet_802.3
INT 5
PORT 300
MEM D8000
Frame Ethernet_II
Frame Ethernet_802.2
Frame Ethernet_SNAP
The following NET.CFG is for a computer with a IBM Token Ring 16/4
Network Adapter. You may need additional entries in your NET.CFG
file, depending on the way your network is set up.
Lines shown here in bold type are added when you install Windows for
Workgroups 3.11.
SHOW DOTS=ON
FILE HANDLES=60
Link Driver TOKEN
Frame Token-Ring
2.3.2 IPX.COM Support
When you install Windows for Workgroups 3.11 with IPX.COM support,
the following lines are added to your SYSTEM.INI file:
[386Enh]
network=*vnetbios,*vwc,vnetsup.386,vredir.386,vserver.386
transport=
secondnet=vnetware.386,vipx.386
netmisc=
netcard=
InDOSPolling=FALSE
netcard3=nwsup.386,nwnblink.386
OverlappedIO=Off
[network]
multinet=netware3
winnet=wfwnet/00025100
DirectHost=No
[NetWare]
NWShareHandles=FALSE
RestoreDrives=TRUE
[network drivers]
netcard=
transport=
devdir=C:\WINDOWS
LoadRMDrivers=No
[NWNBLINK]
LANABASE=0
The following lines are added to your PROTOCOL.INI file (example for
a NE2000 network adapter):
[network.setup]
version=0x3110
netcard=ms$nwsupnb,1,MS$NWSUPNB,2
lana0=ms$nwsupnb,1,mono
[MS$NWSUPNB]
[NWSUP]
Adapters=MS$NWSUPNB
2.3.3 IPXODI.COM and LSL.COM support over an ArcNet Network
When you install Windows for Workgroups 3.11 with IPXODI.COM and
LSL.COM support over an ArcNet network, the following lines are added
to your SYSTEM.INI file:
[386Enh]
network=*vnetbios,*vwc,vnetsup.386,vredir.386,vserver.386
transport=
secondnet=vnetware.386,vipx.386
netmisc=
netcard=
InDOSPolling=FALSE
netcard3=nwsup.386,nwnblink.386
OverlappedIO=Off
[network]
multinet=netware3
winnet=wfwnet/00025100
directhost=no
[NetWare]
NWShareHandles=FALSE
RestoreDrives=TRUE
[network drivers]
netcard=
transport=
devdir=C:\WINDOWS
LoadRMDrivers=No
[NWNBLINK]
LANABASE=0
The following lines are added to your PROTOCOL.INI file:
[network.setup]
version=0x3110
netcard=ms$nwsupnb,1,MS$NWSUPNB,2
lana0=ms$nwsupnb,1,mono
[MS$NWSUPNB]
[NWSUP]
Adapters=MS$NWSUPNB
2.3.4 IPX.COM Support with an ArcNet Network
When you install Windows for Workgroups 3.11 with IPX/SPX support
over an ArcNet network, the following lines are added to your
SYSTEM.INI file:
[386Enh]
network=*vnetbios,*vwc,vnetsup.386,vredir.386,vserver.386
transport=
secondnet=vnetware.386,vipx.386
netmisc=
netcard=
InDOSPolling=FALSE
netcard3=nwsup.386,nwnblink.386
OverlappedIO=Off
[network]
multinet=netware3
winnet=wfwnet/00025100
directhost=no
[NetWare]
NWShareHandles=FALSE
RestoreDrives=TRUE
[network drivers]
netcard=
transport=
devdir=C:\WINDOWS
LoadRMDrivers=No
[NWNBLINK]
LANABASE=0
The following lines are added to your PROTOCOL.INI file:
[network.setup]
version=0x3110
netcard=ms$nwsupnb,1,MS$NWSUPNB,2
lana0=ms$nwsupnb,1,mono
[MS$NWSUPNB]
[NWSUP]
Adapters=MS$NWSUPNB
2.3.5 MSIPX support
Although we recommend that you upgrade from the MSIPX protocol to
either the IPXODI or IPX/SPX protocol, you can keep your MSIPX
support. This section describes the changes that are made to your
system files if you choose to keep MSIPX support when you upgrade
from Windows for Workgroups 3.1 to Windows for Workgroups 3.11.
The following lines are removed from CONFIG.SYS:
C:\WINDOWS\PROTMAN.DOS /I:C:\WINDOWS
C:\WINDOWS\WORKGRP.SYS
C:\WINDOWS\<NDIS MAC driver>.DOS
C:\WINDOWS\MSIPX.SYS
The above lines are replaced by:
DEVICE=C:\WINDOWS\IFSHLP.SYS
The following is an example of a typical AUTOEXEC.BAT file once you
have upgraded to Windows for Workgroups 3.11
C:\WINDOWS\SMARTDRV.EXE /X
C:\WINDOWS\net start
C:\WINDOWS\msipx
C:\WINDOWS\netx
PROMPT $p$g
PATH C:\WINDOWS;C:\DOS
SET TEMP=C:\WINDOWS\TEMP
The following lines in SYSTEM.INI affect running Windows for
Workgroups 3.11 with MSIPX:
[386Enh]
network=*vnetbios,*vwc,vnetsup.386,vredir.386,vserver.386
transport=netbeui.386,nwlink.386,nwnblink.386
secondnet=vnetware.386
OverlappedIO=off
netmisc=ndis.386,ndis2sup.386,vipx.386
netcard=declan.386
InDOSPolling=FALSE
[network]
multinet=netware3
winnet=wfwnet/00025100
DirectHost=No
[NetWare]
NWShareHandles=FALSE
RestoreDrives=TRUE
[network drivers]
netcard=depca.dos
transport=*netbeui,msipx.sys,ndishlp.sys
devdir=C:\WINDOWS
LoadRMDrivers=Yes
[NWNBLINK]
LANABASE=1
This is a sample PROTOCOL.INI file for a computer using Windows for
Workgroups 3.11 with MSIPX. The adapter is a DEC Etherworks Turbo/TP
Network Adapter.
[network.setup]
version=0x3110
netcard=ms$ewtrbtp,1,MS$EWTRBTP,3
transport=ms$netbeui,NETBEUI
transport=ms$ipx,MS$IPX
transport=ms$nwlinknb,NWLINK
transport=ms$ndishlp,MS$NDISHLP
lana0=ms$ewtrbtp,1,ms$ipx
lana1=ms$ewtrbtp,1,ms$netbeui
lana2=ms$ewtrbtp,1,ms$nwlinknb
lana3=ms$ewtrbtp,1,ms$ndishlp
[protman]
DriverName=PROTMAN$
PRIORITY=MS$NDISHLP
[MS$EWTRBTP]
DriverName=DEPCA$
RamAddress=0xD800
Interrupt=5
MaxMulticast=8
MaxTransmits=16
IOAddress=0x300
AdapterName=DE200
[MS$IPX]
DriverName=IPX$
MediaType=Novell/Ethernet
BINDINGS=MS$EWTRBTP
[LANCE]
Adapters=MS$EWTRBTP
[NETBEUI]
DriverName=netbeui$
SESSIONS=10
NCBS=12
BINDINGS=MS$EWTRBTP
LANABASE=0
[NWLINK]
BINDINGS=MS$EWTRBTP
[MS$NDISHLP]
DriverName=ndishlp$
BINDINGS=MS$EWTRBTP
NOTE: Windows for Workgroups 3.11 Setup will detect MSIPX when
upgrading from Windows for Workgroups 3.1 and install support for it.
If you change your network configuration after upgrading to Windows
for Workgroups 3.11, however, Setup may remove MSIPX support, and you
will not be able to reinstall support for it. If this is the case,
you will have to upgrade to either IPX.COM, or IPXODI.COM and
LSL.COM.
KBCategory: kbnetwork kb3rdparty kbref
KBSubcategory:
Additional query words:
wfw wfwg 3.11
Keywords :
Version : WINDOWS:3.11
Platform : WINDOWS
Issue type :