PC Tools May Prevent WFWG From Starting in Enhanced Mode

ID: Q90932


The information in this article applies to:
  • Microsoft Windows for Workgroups version 3.1


SUMMARY

Windows for Workgroups may not start in 386 enhanced mode if the PC Tools VxD VDMAD.386 file is present in either the WINDOWS or WINDOWS\SYSTEM directory.

To correct this problem, remove the PC Tools VDMAD.386 file and expand the Windows for Workgroups VDMAD.386 file from the original disks.


MORE INFORMATION

Windows for Workgroups and PC Tools version 7.x use a VxD called VDMAD.386. This file should reside in the WINDOWS\SYSTEM directory. This file is referenced in the SYSTEM.INI file's [386Enh] section on the line:


   DEVICE=VDMAD.386 
The Windows for Workgroups VxD can be identified by its date, which should be 10/01/92, and its file size, which should be 12246 bytes.

When PC Tools version 7.x is installed after Windows for Workgroups, the PC Tools installation may overwrite the Windows for Workgroups VxD file VDMAD.386 with the PC Tools VxD file VDMAD.386. If this is the case, delete or rename the VDMAD.386 file in the WINDOWS\SYSTEM directory and expand the Windows for Workgroups VDMAD.386 file from the original disks.

If the PC Tools VxD VDMAD.386 file is located in the WINDOWS directory, Windows for Workgroups may load this file instead of the correct Windows for Workgroups VxD from the WINDOWS\SYSTEM directory. If this is the case, first verify that the correct VDMAD.386 file is located in the WINDOWS\SYSTEM directory (by checking the date), and then delete or rename the VDMAD.386 located in the WINDOWS directory.

PC Tools is manufactured by Central Point Software, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: 3.10 3.1 wfwg pc-tools

Keywords :
Version : WINDOWS:3.1
Platform : WINDOWS
Issue type :


Last Reviewed: October 26, 1999