DOCERR: L1008 Error from Incorrect /SEGMENTS Option Syntax

ID: Q80130


The information in this article applies to:
  • Microsoft LINK for MS-DOS, versions 3.x, 4.x, 5.0x, 5.1x, 5.2, 5.3x, 5.5, 5.6
  • Microsoft LINK for OS/2, versions 5.0x, 5.1, 5.11, 5.13, 5.15


SYMPTOMS

An attempt to link an application fails and Microsoft LINK generates the following message:

LINK : fatal error L1008 : Segment limit set too high.


CAUSE

The LINK command line includes the /SE[GMENTS] option and the :<number> parameter is missing, or white space appears before or after the colon (:) character.


RESOLUTION

Modify the LINK command line to use the correct syntax for the option, as follows:


   /SE[GMENTS]:number 


MORE INFORMATION

The following references document the /SEGMENTS option incorrectly:

  • Microsoft FORTRAN "Environment and Tools" manual for version 5.1, page 384.


  • Microsoft FORTRAN version 5.1 for MS-DOS online help.


  • Microsoft Macro Assembler "Programmer's Guide" manual for version 6.0, page 359.


  • Microsoft Macro Assembler version 6.0 for MS-DOS (MASM) online help.


  • Microsoft QuickC for Windows "Toolkit" manual for version 1.0, page 217.


  • Microsoft QuickC version 1.0 for Windows (QC/Win) online help.


Each of these references document the /SEGMENTS option as follows

   /SE[GMENTS][:number] 
indicating that the :<number> parameter is optional.

Additional query words: 3.00 3.01 3.02 3.04 3.05 3.06 3.51 3.55 3.60 3.61 3.64 3.65 3.69 4.06 4.07 4.10 5.01.20 5.01.21 5.02 5.03 5.05 5.10 5.11 5.13 5.15 5.20 5.30 5.31.009 5.50 5.60

Keywords : kb16bitonly
Version : MS-DOS:3.x,4.x,5.0x,5.1x,5.2,5.3x,5.5,5.6; OS/2:5.0x,5.1,5.11,5.13,5.15