The information in this article applies to:
SUMMARYLinear address mode display drivers must save the extended portions of the CPU registers. Some enhanced mode grabbers assume that the display driver does save these register portions. Windowed MS-DOS sessions can become filled with 'garbage' if the display driver does not save the extended CPU register portions. SYMPTOMS
When an MS-DOS session is opened to full screen and then converted to a
windowed shell, the client area is filled with text-like 'garbage'. If a
DIR or CLS command is issued, the windowed MS-DOS session is filled with
the correct information at the point where the command was entered. Any
scrolling thereafter displays the correct information.
CAUSEThe cause of this type of problem is a 'trashing' of the high part of some register(s) by the display driver. When the display grabber receives the execution focus with corrupted registers, the result is screen garbage. RESOLUTIONModify your display driver so that it saves the extended portions of registers before using them and restores them after your through. Do not assume that the extended portions of the CPU registers are free to trash. MORE INFORMATION
While it could be argued that it is not required to save the high portions
of the CPU registers, the fact is that there are grabbers out there that
assume otherwise. At a minimum, you need to make sure to save and restore
processor registers ESI,EDI in BitBlt(). It is likely that your driver code
is saving and restoring SI,DI but you are using ESI,EDI, which means the
high part of ESI,EDI is not being preserved correctly. There may also be a
need to save the other extended registers as well.
Additional query words: 3.10 DDK display driver