Timer2.exe - Timers and Timing in Microsoft Windows

ID: Q81592


The information in this article applies to:
  • Microsoft Windows Software Development Kit (SDK) versions 3.0, 3.1


SUMMARY

Timer2.exe is a file that contains the text of this article in the Windows Help file format. The following is the text of the article "Timers and Timing in Microsoft Windows".


MORE INFORMATION

The following file is available for download from the Microsoft Download Center. Click the file name below to download the file:

Timer2.exe
For more information about how to download files from the Microsoft Download Center, please visit the Download Center at the following Web address
http://www.microsoft.com/downloads/search.asp
and then click How to use the Microsoft Download Center.

This article covers the following aspects of timers and timing in the Microsoft(R) Windows(TM) graphical environment:
  • How Windows-based applications set up and use timers to perform an operation periodically


  • Limitations of timers


  • Creating and destroying timers using the SetTimer and KillTimer functions


  • How timer events are detected, recorded, and dispatched internal to Windows


  • How standard and enhanced modes affect timers and timing


  • How TOOLHELP.DLL can be useful to timers


  • A description of the INT 2Fh interface to the virtual timer driver (VTD.386)


TIMERS AND THEIR USES

Microsoft Windows timers create an event that periodically triggers a specific action in an application. The event can be a WM_TIMER message returned from a GetMessage or a PeekMessage function, or it can be a call to a specified function.

Timers are used in many ways. For example, the Windows Clock application uses a timer to awaken the application periodically to update the clock face. Internally, carets flash on timer events. Also, the rate at which list boxes and edit controls scroll is based on timer events. Without timers, the application would remain active in delay loops, violating the "give up control when you are not active" rule needed to keep the nonpreemptive tasking model of Windows running.

Instead, a Windows-based application creates a timer with an appropriate delay and then suspends itself in a standard GetMessage loop. When the timer delay expires, the timer event is generated, and the application can perform the necessary operation. At this point the timer can either be destroyed or be left active. If it is left active, another timer event is generated when the timer delay again expires. This cycle continues until the timer is destroyed. Windows version 3.0 can maintain only 16 active timers; Windows version 3.1 can maintain only 32 active timers. Therefore, an application that is not actively using a timer should destroy it so the timer can be used by another application.

Tip: Timers are a limited resource. If all timers are in use, the SetTimer function fails. Unless keeping a timer active is absolutely essential to a program, the application must destroy the timer when it is not in use.

Creating and Destroying a Timer

A timer is created when a program calls the SetTimer function. A timer can dispatch a message to a particular window or call a specified callback function. The lpTimerFunc parameter to SetTimer determines whether a message is sent or a callback function is called. When GetMessage and PeekMessage determine that a timer event has occurred, they return a WM_TIMER message. The lParam of this message contains the lpTimerFunc value passed to SetTimer. The code in DispatchMessage examines the lParam of the WM_TIMER message and dispatches the message to the appropriate window procedure if the lParam is NULL, or calls the callback if the lParam is not NULL. If the lpTimerFunc parameter contains a non-null value, it is assumed to be the FARPROC address of an exported callback function (use MakeProcInstance on it too). This parameter must be correct because Windows does not validate it. Windows simply makes a far call to the specified address. The format of the callback is described in the Microsoft Windows Software Development Kit (SDK) documentation for the SetTimer function, but the following table better describes the parameters to the callback.

   Parameter Description
   --------- -----------

   hWnd      The window handle that was passed as the hWnd parameter to
             the SetTimer function. Because Windows never looks at this
             parameter, you can pass a NULL here if the callback doesn't
             need an hWnd or if no hWnd is available at the time SetTimer
             is called.

   wMsg      Always WM_TIMER.

   nIDEvent  The timer's ID.

   dwTimer   DispatchMessage calls the GetTickCount function and then
             passes the value obtained in dwTimer. 
If the lpTimerFunc parameter to SetTimer is NULL, the timer generates a WM_TIMER message for the window specified by the hWnd parameter. The lParam of the WM_TIMER message returned from GetMessage or PeekMessage is NULL, which causes DispatchMessage to send the message to the appropriate Windows procedure. If hWnd is not a valid window handle, DispatchMessage returns an "Invalid Window Handle" FatalExit (code 0x0007). When the window procedure gets the WM_TIMER message, the wParam contains the timer's ID, and the lParam is NULL.

When a timer is created, it is assigned an ID. Timer IDs are passed to timer callback functions and with WM_TIMER messages. Timer IDs are also used when killing the timer with the KillTimer function. The nIDEvent parameter lets an application choose the timer's ID if the hWnd parameter is not NULL. If the hWnd parameter is NULL, Windows chooses an ID and returns it from the SetTimer function. In this case, the nIDEvent parameter is ignored, regardless of the value of lpTimerFunc.

The return value from SetTimer is 0 (zero) if the timer could not be created. This situation occurs only when all timers are in use before the function is called. SetTimer returns a nonzero value if the timer is successfully created. If the hWnd parameter is NULL, this nonzero value is the timer's ID. If hWnd is nonzero, the function succeeded, and the timer's ID is the value passed in nIDEvent. The timer's ID must be saved because it will be needed later to kill the timer.

Tip: If the application calls SetTimer with a nonzero hWnd, it must specify the timer ID. Contrary to the Windows version 3.0 documentation, this ID, not the SetTimer return value, must be used when killing the timer.

If SetTimer is called with exactly the same hWnd and ID as an already active timer, Windows resets the timer rate to the new value passed in the wElapse parameter. This method is convenient for changing the rate of a timer without having to kill it and create a new one. Note that if hWnd is NULL, the ID value passed must be the timer's ID as returned from the preceding SetTimer call.

In all flavors of SetTimer, the timer event rate is passed in the wElapse parameter. It is specified in milliseconds but is not nearly that precise.

A timer is killed by calling the KillTimer function. KillTimer requires two parameters: the hWnd that was passed to SetTimer when the timer was created and the timer's ID. Note again that if hWnd is NULL, the timer's ID is the return value from the SetTimer call, not the value passed in the nIDEvent parameter.

Timer Implementation and the Effect on Timer Resolution

All ISA (IBM PC/AT and compatible) computer systems generate a hardware interrupt on IRQ0 18.2 Hz. This interrupt is mapped to INT 8 and can be intercepted by any application that wants to hook it. At 18.2 Hz, the interrupt occurs approximately once every 55 milliseconds. The Windows system driver hooks INT 8 and maintains the value returned by the GetTickCount function. Thus, this value is accurate only to within 55 milliseconds.

Interrupt-level timer services via INT 8 are fairly straightforward and easy to understand. Providing timer services to a Windows-based application is much more difficult. The two major complications are the inability to call Windows-based applications at interrupt level and the nonpreemptive nature of the Windows tasking model. A timer event for a Windows-based application must behave the same as other interrupt-driven events such as mouse and keyboard events: The event must be detected and recorded at interrupt level but dispatched only to the appropriate application the next time the application asks for messages. Therefore, the delay between the interrupt event occurring and the application receiving it is nondeterministic.

Although the hardware timer rate is 18.2 Hz, the rate at which Windows-based applications receive timer messages is quite a bit slower and is affected by other applications that are running.

Windows hooks INT 8 at initialization time. As a timer is created, a timer data structure is reserved for the timer. This data structure contains information about the timer, such as which hWnd to send the message to or which FARPROC to call, the timer ID, or the delay time between events. This delay time is then copied into a current delay counter. When the INT 8 handler is called, the current delay counter for each active timer is decremented by 55 (because the delay time is specified in milliseconds). If in doing so the current delay counter reaches 0, a flag is set to indicate that an event should be generated for this timer.

GetMessage and PeekMessage first check to see if any posted messages or any keyboard or mouse events are waiting for the application. If none are, GetMessage and PeekMessage check to see if any timers created by the active application have triggered. If one of these timers has triggered, GetMessage and PeekMessage create a WM_TIMER message with the appropriate wParam and lParam and return the message. Contrary to the SDK documentation, the message is never placed in the applications queue. DispatchMessage properly dispatches the message either to the appropriate window or to the specified callback function.

When a timer is created, it is associated with the currently active task. When GetMessage and PeekMessage scan for timer events, they look only at timers associated with the currently active task. Although not normally a problem, this activity does prevent an application from creating a timer that would dispatch WM_TIMER messages to a window in another task. Also, timers should not be created in systemwide hooks such as the keyboard hook because the hook is likely to be called while another task is active.

Tip: Be careful with SetTimer calls inside dynamic-link libraries (DLLs). If a DLL creates a timer on behalf of a task and then the task terminates, the timer is destroyed.

ENHANCED-MODE VIRTUALIZATION

When running in enhanced mode, Windows takes advantage of the virtual machine (VM) capabilities of the Intel386(TM) hardware. All MS-DOS-based applications run as if each had the entire system to itself. All Windows-based applications run together in a single VM. All VMs, if none are paged, reside simultaneously in physical memory, but only one at a time is active. To arbitrate among the VMs, Windows loads a virtualization layer when running in enhanced mode. This layer acts as a traffic cop, directing hardware events to the appropriate VM on the basis of which VM is active.

One of the many hardware events that is virtualized is INT 8, the timer. When a VM is not the active VM, it does not receive INT 8 events at the standard 18.2 Hz rate. The Windows VM not receiving INT 8 events at a standard rate plays havoc with the value returned by the GetTickCount function as well as with any active timers set by Windows- based applications. In this environment, WM_TIMER messages are at the mercy of the enhanced-mode scheduler and the relative priority of the Windows VM. Probably more problematic is the value returned from GetTickCount. Because this value increments by 55 only when the Windows VM sees an INT 8, it is not at all accurate in enhanced mode. Applications that require accurate event timing must not use GetTickCount to determine time delays. Instead, they must use the clock maintained by MS-DOS (INT 21H, function 2CH), TOOLHELP.DLL services, or the VTD (described below).

Tip: Windows timers operate erratically in enhanced mode when MS-DOS-based applications are active.

Tip: The GetTickCount function cannot be used to time events accurately because it is not regularly updated when the MS-DOS VMs are active. GetTickCount is inaccurate both in standard mode and in enhanced mode.

STANDARD-MODE TASK SWITCHING

Standard-mode task switching has essentially the same effect on the GetTickCount value and Windows timers as does enhanced-mode virtualization, but for a different reason. When a task is switched in standard mode, either between an MS-DOS-based application and Windows or between two MS-DOS-based applications, Windows swaps the entire running application to disk and then loads the new application from its previously saved swap file. While running an MS-DOS-based application, the Windows INT 8 handler obviously is not being called because Windows is not in memory. Thus, any active timers do not count down, and the GetTickCount value does not increment. This problem is less obvious in standard mode than in enhanced mode because MS-DOS-based applications cannot run in a window in standard mode.

USING TOOLHELP.DLL

TOOLHELP.DLL is a new library being developed for Windows version 3.1, but it will also run under Windows version 3.0. It was developed for use by debuggers and profilers, but its ability to provide high- resolution timing services is useful to other types of Windows-based applications. The TimerCount function can return system time information that is accurate to the millisecond. The function returns two values: a count of how long Windows has been running and a cumulative total of how long the Windows VM has been active. In standard mode, both values are the same and contain the time Windows has been running; however, the counts are accurate only if no task switches take place, because they are not maintained while MS-DOS-based applications are active.

VIRTUAL TIMER DEVICE

The virtual timer device (VTD) provides timer services that are more accurate than the value returned by GetTickCount. TOOLHELP.DLL provides a convenient way to access the VTD services via the TimerCount function. Under some conditions, however, calling TimerCount is not possible or appropriate. Under these rare conditions, an application can call the VTD directly. The VTD in Windows version 3.1 is the first version of the VTD that supplies these timer services.

The VTD uses the 8253 Programmable Interval Timer chip to obtain its values. The 8253 countdown register is always set to FFFFh, and the rate is set to 1.196 MHz. Thus, an interrupt is generated about 18.2 times per second, or roughly every 55 milliseconds. This is the interrupt that comes through INT 8. The countdown register of the 8253 is accessible at any time, and the VTD uses it to obtain more accurate time information than is available through INT 8.

The address of the function in the VTD that provides these timer services is obtained in a slightly roundabout way. The application must execute an INT 2Fh instruction with the AX register set to 1684h and the BX register set to 5. This instruction returns the address of the VTD timer services function in ES:DI.

The following values can be obtained from the VTD by calling this function with the appropriate value in the AX register.

Version Number

The VTD version number is obtained by calling the VTD with AX set to 0. The major version number is returned in AH, and the minor version number is returned in AL. The version number does not change to match the version of Windows with which the VTD is shipped. Instead, the version number changes when any modifications or additions are made to the services provided. The version values returned from the VTD in Windows version 3.1 are AH set to 3 and AL set to 0Ah.

Current Clock Tick Time

The VTD maintains a 64-bit value that is accurate to 0.8 microseconds. This value is obtained by calling the VTD with AX set to 0100h. The 64-bit value is returned in EDX:EAX. The returned value indicates the time Windows has been running based on a 1.196 MHz clock.

Current System Time in Milliseconds

The VTD also maintains the time in milliseconds Windows has been running. This value can be obtained by calling the VTD with AX set to 0101h. The 32-bit result is returned in the EAX register. This value is not affected by changes in VM activation.

Current VM Time in Milliseconds

The cumulative time the current VM has been active can be obtained by calling the VTD with AX set to 0102h. The 32-bit result is returned in the EAX register. The value returned is the cumulative amount of time that the VM that is active at the time of the call has been active.

All applications will incur an overhead when calling the VTD (also when calling TOOLHELP.DLL because it, in turn, calls the VTD). Calling the VTD causes a ring transition because the VTD runs in ring 0. Ring transitions are about 100 times slower than a far call but still take less than 1 millisecond. The overhead for a ring transition to the VTD is constant.

Copyright 1992 by Microsoft Corporation. All rights reserved.

Additional query words: