Setup From CD Might Fail On The Compaq SystemPro XL

ID: Q104220


The information in this article applies to:
  • Microsoft Windows NT 3.1
  • Microsoft Windows NT Advanced Server, version 3.1


SYMPTOMS

Setting up Windows NT or Windows NT Advanced Server from the CD-ROM drive on the COMPAQ SystemPro XL with the embedded SCSI controller IRQ set to 2(9) will make the computer stop responding (hang) at the status message "Running CHKDSK" after Setup has formatted the newly-created partitions.


CAUSE

The COMPAQ SystemPro XL with an embedded SCSI controller is detected as a NCR53c9x during setup. If the CD-ROM drive is connected to this controller, there is a known problem if the controller is configured in the EISA configuration using IRQ 2/9.


RESOLUTION

Reconfigure the controller to use any other unused IRQ such as 5.

To reconfigure the controller to use another IRQ, do the following:

  1. Run the COMPAQ EISA Configuration Utility.


  2. Choose Configure Computer.


  3. Choose View Or Edit Details.


  4. Press the PAGE DOWN key or the DOWN ARROW key to select Controller.


  5. Press the F6 key to "Edit resources."


  6. Change "Interrupt (IRQ)" from 2(9) to an unused interrupt. (5 is often unused).


Additional query words: prodnt

Keywords : kbother
Version : winnt:3.1; :3.1
Platform : winnt
Issue type :


Last Reviewed: January 11, 2000