PRB: Netbios RESET Cannot Be Called with Pending Commands

ID: Q125659


The information in this article applies to:
  • Microsoft Win32s versions 1.2, 1.25


SYMPTOMS

A Win32-based application cannot call the Netbios RESET command as long as there are asynchronous commands still pending.


CAUSE

This behavior is by design in Win32s.


RESOLUTION

The application should cancel all pending commands, and wait for the post routines of all the pending commands to be called. After that, the application can issue a Netbios RESET command.


STATUS

This behavior is by design but may be designed differently in a future version of Win32s.

Additional query words: 1.20

Keywords :
Version : WINDOWS:1.2,1.25
Platform : WINDOWS
Issue type :


Last Reviewed: January 18, 2000