Error 234 When Using NET VIEW in Windows for Workgroups 3.11

ID: Q127764


The information in this article applies to:
  • Microsoft Windows NT 3.1
  • Microsoft Windows NT Advanced Server, version 3.1
  • Microsoft Windows NT Workstation versions 3.5, 3.51, 4.0
  • Microsoft Windows NT Server versions 3.5, 3.51, 4.0
  • Microsoft Windows for Workgroups


SYMPTOMS

When you run NET VIEW from a Windows for Workgroups version 3.11 client system to view the shares on a Windows NT computer, the following error message appears:

Error 234
If you attempt a similar operation in Windows for Workgroups File Manager by selecting a Windows NT computer, the following error message appears:
An internal Lanman error has occurred.


CAUSE

There may be a corrupt share on the Windows NT computer.


RESOLUTION

To correct this problem, try one or more of the following steps:

  • Disconnect from all shares on the Windows NT computer (including hidden shares such as c$ and ipc$) and then reestablish the connections.


  • If long share names are being used for either file shares or printer shares, try renaming the share to contain no more than 12 characters.


  • Delete all the shares on the server and then recreate them.


Additional query words: prodnt 3.10 3.11 wfw wfwg

Keywords : NTInterop
Version : WINDOWS:; winnt:3.1,3.5,3.51,4.0; :3.1
Platform : WINDOWS winnt
Issue type :


Last Reviewed: November 1, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.