Runtime Error 1226 Occurs When Using Diagnostic Playback

ID: Q233551


The information in this article applies to:
  • Microsoft COM Transaction Integrator for CICS and IMS, version 4.0 SP2
  • Microsoft SNA Server, version 4.0SP2


SYMPTOMS

When you use a COM Transaction Integrator for CICS and IMS (COMTI) component library in a COMTI Diagnostic Playback Remote Environment (RE), the following error may be recorded in the application Event Log.

Event ID: 102
Source: COMTI
Type: Error
Category: General

(102) COM Transaction Integrator reported the following exception to the client:

Component: Cedar.Bank.1
Method: cedrbank

Exception description:
(1226) COM Transaction Integrator encountered an unexpected error while preparing to connect to the Remote Environment (hr=0xc0000835). Delete and re-create the Remote Environment.


CAUSE

This error may occur if the RE is renamed.


WORKAROUND

The error is transient. Simply try the method again, and the error should not reoccur.


STATUS

Microsoft has confirmed this to be a problem in Microsoft SNA Server version 4.0.

Additional query words:

Keywords : sna4sp2
Version : WINDOWS:4.0 SP2,4.0SP2
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: June 11, 1999