INF: Sample PU Statement in Worksheet Produced by Mainframe APPC/LU6.2 Wizard is Inaccurate

ID: Q239858


The information in this article applies to:
  • Microsoft COM Transaction Integrator for CICS and IMS, versions 1.0, 4.0 SP2
  • Microsoft SNA Server, version 4.0 SP2


SUMMARY

The sample mainframe physical unit (PU) definition contained in worksheet 1 of 2 produced by the Mainframe APPC/LU6.2 Wizard includes the following parameter:

CONNTYPE=APPN
with the following comment:
needed for parallel sessions
Most of the time, it is not necessary to code this line. Moreover, coding it can cause additional problems. The recommendation is to NOT code this line unless it is specifically required after consultation with the mainframe communication system (VTAM) programmer.

Additional query words:

Keywords : sna4sp2
Version : WINDOWS:1.0,4.0 SP2
Platform : WINDOWS
Issue type : kbinfo


Last Reviewed: September 23, 1999