DTM_SETRANGE

This message sets the minimum and maximum allowable system times for a date and time picker (DTP) control.

At a Glance

Header file: Commctrl.h
Windows CE versions: 2.0 and later
Related macro: DateTime_SetRange

Syntax

DTM_SETRANGE wParam = (WPARAM) flags;
lParam = (LPARAM) lpSysTimeArray;

Parameters

flags

Specifies which range values are valid. It can be a combination of the following values:

Value Description
GDTR_MIN The first element in the SYSTEMTIME structure array is valid and will be used to set the minimum allowable system time.
GDTR_MAX The second element in the SYSTEMTIME structure array is valid and will be used to set the maximum allowable system time.

lpSysTimeArray

Long pointer to a two-element array of SYSTEMTIME structures. The first element of the SYSTEMTIME array contains the minimum allowable time. The second element of the SYSTEMTIME array contains the maximum allowable time. It is not necessary to fill an array element that is not specified in the flags parameter.

Return Values

Nonzero indicates success. Zero indicates otherwise.