13 The Printer Font Metric Dialog Box

The following error messages are associated with the Printer Font Metric
(PFM) dialog box.

List                     Description
---------------------------------------------------------------------------

minidriver name :Type    UniTool issues this message if the value in the
must = 128               Type box does not equal 128.

minidriver name          UniTool issues this message if a point size value
:Points must be > 0      that is less than or equal to zero is entered.

minidriver name          UniTool issues this message if a vertical
:VertRes must be > 0     resolution value that is less than or equal to
                         zero is entered.

minidriver name          UniTool issues this message if a horizontal
:HorizRes must be > 0    resolution value that is less than or equal to
                         zero is entered.

minidriver name          UniTool issues this message if a value in the
:Ascent must be > 0      Ascent box that is less than or equal to zero is
                         entered.

minidriver name          UniTool issues this message if a value in the
:Weight should be 400    weight box that is not equal to either 400 or 700
or 700                   is entered.

minidriver name          UniTool issues this message if a value in the Char
:CharSet must be 0,1,    Set box that is not equal to 0, 1, or 2 is entered.
or 2                     

minidriver name          UniTool issues this message if a negative value is
:AvgWidth must be > 0    entered in the Average Width box.

Kerning Info will be     UniTool issues this message if kerning information
lost! Continue?          will be lost.